The New Conventional fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. With their clean and attractive contemporary design, they fits with any decor. The basic and intuitive user interface with icons make easy their application everywhere without an additional language kit required. With support for multiple lines of conventional detectors and accessories, these quick-to-configure systems offer versatility that benefits building owners and installation/maintenance companies alike.

The panel

The NC-PF2 is a conventional fire alarm control panel. It is supplied with 2 zones that support up to 32 devices per zone, as well as up to 2 supervised relay outputs dedicated to sounder control. In addition 2 conventional relay outputs dedicated to common fire and fault conditions, as well as two user configurable inputs for monitoring and control are available.

No Language Kit required for localization.

Options

The panels support 2 types of auxiliary relay boards, one with 4 standard relays, and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 8 additional outputs.

Approvals & Compliance

The product line carries the following accreditations: • EN54:2, EN54:4 and CE approved • CPD certified • WEEE compliant • RoHS compliant Type class conditions: 3K5 of IEC 60721-3-3

Key features:

  • Modern, elegant design with basic and intuitive user interface with icons.
  • Easy removable parts for quick and clean installation
  • Default regional setup modes
  • Normal, head-out & intrinsically safe zone support
  • Supervised alarm notification outputs
  • EN54 compliant potential free fire & fault relays
  • Class change, day/night & remote reset facilities
  • Auxiliary 24 VDC supply output with reset support
  • Default support for special functions such as: - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk test - CleanMe™
  • Auxiliary standard & supervised relay output boards
  • Networkable up to 64 zones
  • No language kit inserts required

Technical specifications:

General
Maximum system capacity (device count)up to 1280
Network size (nodes)up to 32
Electrical
Power supply typeVAC
Power consumption2 A @ 24 VDC
Operating voltage110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%)<br>Cable type: 3 x 1.5 mm² (live, neutral, earth)
Current consumption2 A @ 110/240 VAC<br>130 mA (alarm, no devices) (panel supply)<br>50 mA (quiescent, no devices) (panel supply)
Loop
Maximum loop capacity2
Zone
Maximum zone capacityup to 2
Operating voltage22 VDC (18 to 24 VDC)
Quantity of devices per zone32 max.
Rating65 mA (max. Load)
Cable rating40 ohm (max cable resistance), 500 nF (max cable capacitance)
Input
Input quantity2
Input type and rating100 ohm (max. cable resistance)
Output
Supervisory voltage-15 to +28 VDC
Auxilliary power24 VDC (21 to 28 VDC)
Supervised Outputs2
Load (max.)250 mA
Non Supervised Outputs2
Load2 A @ 30 VDC
Standby battery
Capacity2 x 12 V, 7.2 Ah (SLA)
Physical
Form factorSmall
Physical dimensions320 x 435 x 134 mm (W x H x D)
Net weight2.8 kg (without battery)
Shipping weight4.5 kg
ColourGrey (RAL 7035)
Mounting typeSurface mount
Cable entriesØ 20 mm - 14 / 2 / 12 (top / bottom / rear)
Environmental
Operating temperature-5 to +50°C
Storage temperature-20 to +70°C
Relative humidity10 to 95% noncondensing
EnvironmentIndoor
IP ratingIP30
Regulatory
CompliancyCPD, RoHS, WEEE
CertificationEN54-13, EN54-2, EN54-4
Auxilliary Supply Output
Load (max.)250 mA @ 25°C / 195 mA @ 40°C